Description
Oil heating vacuum drying oven VD-2000P-PC
Key parameters
power input:AC380V 3φ 50HZ
size and rate:
model spec | inner size(mm) | outer size(mm) | power rate |
VD-2000P-PC | W850×D920×H1450 (single zone) | W2000×D2098×H2383 | 30Kw |
temperature control range: RT~150℃
vacuum degree: airpressure~50Pa (resettable)
Ovenstructure
outershell:galvanized cold rolled steel
liner:stainless steel 304
heatresistant: 100mm silicone insulated cotton
vacuumblower: special designed vacuum blower
1) fast achieving uniform heatdistribution
2) cooling with the conductionoil
nitrogenpressure control: 1.0 bar ± 0.05bar (100000pa ± 5000pa);
Hot oil heatingsystem
hot oil heatingsystem diagram
Construction andcontrol
1)oil furnace: heavy duty structure soldered with seamless structural steel,alumina silicate fiber for heat resistant, and high temperature cut-off valveembedded between the furnace and the oil pump.
2)Electric heater: flanged heater with heating tube made of 1Cr18Ni9Ti,heating wires made of Cr20Ni80, and filler of magnesia powder, with high heatand pressure resistance.
3)Professional high temperature hot oil pump, safe guarantee for long timeno leakage working, inside which there are three oil circulation tubes toensure the even heating.
4)Temperature control, PID control system
5)Pressure monitor: there’s pressuregauge on the tubes of the hot oil pump and the heating tube to reflect the realpressure inside the furnace, and it will give alarm to stop the heating whenpressure goes unnormal.
6)Liquid level monitoring: there’s monitoring system for the liquid level,and it will give alarm to stop heating when the liquid levels down.
7)Key alarming system: audible and visual alarm for overheating, lowpressure, low liquid level, etc.
8)Overall protection system: the protection system is based on chainreaction for the key parameters like liquid level, temperature, etc., anyunnormal figure will trigger off the alarming system and react to stop theheating for overall protection.
Electric system
Omron PLC
PC operation system
temperature monitor: 6 profiles of temperature recording and monitoring,with diagram available
Security protection
overcurrent protection
system short circuit protection
overvoltage protection
vacuum pump overloading protection
open-phase protection
Overtemperature protection